Gas boiler clicks

Despite the novelty and noiselessness in the process, the device is characterized by periodic occurrence of various malfunctions in the form of characteristic sounds. This does not pose a serious threat to the user and residents of the house, however, discomfort in management appears. In this article, we will consider not only the sources of problems why a gas boiler clicks, but also the methods for eliminating them.

When clicks occur

They can appear in such cases as turning on a structure, turning it off, during cooling, during heating. Let's analyze each situation in more detail:

  1. When the consumer turns on the stove, a sufficiently large amount of gas can accumulate. When a spark appears, respectively, the substance flashes and a noise is heard. This may be due to a defect in the three-code valve or in the ignition system. In the last of the incidents, there is a possibility that the spark appears much later than is actually necessary. In addition to these reasons, there may be a risk of clogging or defective smoke exhaust. This leads to the formation of an undesired mixture of gas and air. If the wick becomes dirty, claps can also be heard. If it is not eliminated, then, most likely, the thrust over time will represent poor performance.
  2. In the process of heating, the hinged brackets may be incorrectly installed due to which an imbalance in thermal expansion occurs. Clogging of the mesh at the bottom of the gas stove is also possible. Do not forget about the incorrect performance of the pump - because of this resonance, sounds appear. And perhaps the last option may be the moment when a large amount of liquid evaporates.
  3. Another common manifestation can be a change in temperature indicators to a lower side, that is, cooling of the whole device.
  4. The next, but rare source is not possible to properly mount the pipe. It happens that it is made without taking into account the degree of arbitrary movement with increasing thermal effect. This is easy to notice when the degree of the heat carrier changes.

Causes of clicks

The following are the main and often occurring sparks for housewives of origin:

  • Lime formation.
  • The thermal balance inside the boiler is disturbed.
  • The appearance of various damage to one or more elements of the entire system.

As for the rest, these are basic varieties.

IMPORTANT. Of course, with uncertainty about the correct detection of the source of the defect, it is advisable to contact a special service. Qualified masters will be able not only to establish a diagnosis in a timely manner, but also to independently eliminate it.

How to solve a problem

The correction will depend on the original reason, therefore:

  • With an excess of oxygen in the water, it is necessary to re-equip the entire system. That is, it is necessary to mount the air vents and replace it with a membrane expansion tank.
  • If the whistle comes from the valve, it is advisable to check the settings. This can be done using the recommendations in the instructions.
  • When there is an excess of pump power over design needs, the speed of the process should be reduced.
  • Replacing the valves is also worth the ball valves. But you can put an auxiliary gasket made of rubber.
  • To prevent knocking when the temperature in the radiator changes, you need to change the location of the wall mounts.
  • And in order not to ring the pipes that are intended for heating, it is necessary to lay a special material - merelon - around them. This will contribute to isolation.
  • To eliminate sounds from the heat exchanger, the inside must be cleaned of scale.